Reference
What do building classes 1 to 10 mean?
Building classes are the Building Code of Australia's way of sorting buildings by use. A detached house is class 1a, a block of units is class 2, an office is class 5, a shed is class 10a and a pool or fence is class 10b. QBCC builder licences are written in these terms, so the class of your building decides which licence a builder needs.
The list
| Class | What it is |
|---|---|
| 1a | A single dwelling: a detached house, or attached dwellings separated by a fire-resisting wall, such as a row house, terrace, townhouse or villa unit |
| 1b | A boarding house, guest house or hostel with total floor area not over 300 square metres and no more than 12 residents |
| 2 | A building containing two or more sole-occupancy units, each a separate dwelling |
| 3 | Other residential buildings for unrelated people, such as a backpackers or the residential part of a hotel or motel |
| 4 | The only dwelling in a class 5, 6, 7, 8 or 9 building |
| 5 | An office building |
| 6 | A shop or other building for retail sale or direct service to the public: a cafe, restaurant, hairdresser, showroom or service station |
| 7a, 7b | A car park; a building for storage or wholesale display |
| 8 | A laboratory, or a building where goods are produced, assembled, altered, repaired, packed or cleaned |
| 9a, 9b, 9c | A health care building; an assembly building such as a school, church or sports centre; an aged care building |
| 10a | A non-habitable structure such as a private garage, carport or shed |
| 10b | A fence, mast, antenna, retaining or free-standing wall, swimming pool or the like |
| 10c | A private bushfire shelter |
Definitions are paraphrased from the QBCC's Building classes and licence requirements fact sheet (March 2024), which reproduces them from the Building Code of Australia.
How licences use them
Read a QBCC licence scope with this list beside you and it becomes plain. "Building work on a class 1 or class 10 building" means houses, townhouses and their sheds, carports, fences, retaining walls and pools. All three mainstream builder classes include that line. The differences start at class 2 and are set out in low rise, medium rise or open.
Cases that surprise people
A duplex. Two attached dwellings separated by a fire-resisting wall are class 1a, the same as a house. Two units stacked one above the other are class 2.
A flat above a shop. If it is the only dwelling in the building, it is class 4, and the shop below is class 6. One builder may need a scope that covers both.
A small guest house. Up to 300 square metres and 12 residents is class 1b. The QBCC fact sheet shows a single-storey class 1b under Low Rise and says to refer two and three storey versions to the engaged certifier.
A retaining wall. Class 10b. So is the pool, and so is its fence, which has rules of its own in pool fencing rules.
Who decides the class
The building certifier does, as part of the building approval. The QBCC fact sheet is general guidance limited to standard designs and says so. If your project is close to a boundary between classes, ask the certifier for the classification in writing before you ask builders to quote, because it changes who is allowed to take the job.
Quick answers
What class of building is a house?
Class 1a. The Building Code definition covers a detached house and attached dwellings separated by a fire-resisting wall, such as townhouses and terraces.
What building class is a swimming pool?
Class 10b, the same class as fences, retaining walls, masts and antennas.
Sources
All sources were opened in November 2026.
General information for Queensland home owners, written by the Bluegum Builders editorial desk in November 2026. It is not legal advice. Figures and rules change, so confirm them on the linked QBCC pages before acting.